Choosing a permanent outdoor lighting system starts with the project architecture—not only the fixture. This guide compares four G&D SMART roofline lighting platforms and explains when each model is appropriate.
MODEL SELECTION · QUICK ANSWER
Which G&D SMART Permanent Roofline Light Fits Your Project?
- C5204: choose when 12V, 24V or 36V variants and multiple spacing options are required.
- C5205: choose for a compact 24V, 9-inch RGBW SPI platform with a 20 mm diameter fixture.
- P23A: choose when the smallest published fixture format in this comparison is preferred; confirm the supplied SPI/TTL revision and firmware mapping.
- C5206: choose for a project designed around a 48V architecture; match the 16AWG wiring, M12B 10A connector and 48V GC08 configuration.
Important power-data note: C5204's 0.96W is explicitly defined as maximum mixed-white power with R+G+B+W on together. C5205 and P23A list 0.96W, while C5206 lists 1.00W/module. Do not assume these published figures use an identical test or operating-mode basis without confirming the model-specific datasheet.
Certification note: IP67 is a module rating, not proof that the complete installed system is suitable for Wet Location. Confirm the exact model, revision, cable, connector, control box, certification scope and installation instructions. C5206's model-specific certification record must be requested for the supplied configuration.
Technical Center · System Solutions · Request a product-selection review
Quick comparison
| Model | System voltage | Published power | Spacing | Fixture size | Control | Best fit |
|---|---|---|---|---|---|---|
| C5204 | 12V / 24V / 36V | 0.96W maximum mixed-white planning basis | 4, 6, 9, 12 in; single-piece | Ø30 × 16 mm | SPI | Projects needing multiple voltage and spacing options |
| C5205 | 24V | 0.96W | 9 in | Ø20 × 17.6 mm | SPI | 24V projects using a smaller fixture format |
| P23A | 24V | 0.96W | 9 in | Ø12 × 14.6 mm | SPI; TTL support listed for the model | Projects prioritizing the smallest fixture format |
| C5206 | 48V | 1.00W/module | 9 in | Ø30 × 16 mm | SPI | 48V architecture and longer-distance system planning |
Which model should you choose?
C5204 — the flexible multi-voltage platform
C5204 is the most flexible of the four platforms when a program may use 12V, 24V or 36V configurations or needs multiple spacing options. The exact variant, mounting profile, wiring and GC08 configuration must be matched to the approved project design.
View C5204 · Compare voltage systems
C5205 — compact 24V roofline platform
C5205 is a 24V RGBW SPI platform with a 20 mm diameter and 9-inch published spacing. It is a practical choice when the project is standardized around the 24V GC08 platform and a smaller fixture format is preferred.
P23A — smallest fixture format in this comparison
P23A is a 24V, 9-inch platform with a published 12 mm diameter. The current product information lists SPI control and also references TTL support; confirm the exact supplied revision, protocol and firmware mapping before approval.
C5206 — 48V architecture
C5206 is the 48V platform. Its published specification uses 1.00W per module and 16AWG wiring with an M12B 10A connector in the standard configuration. The 48V architecture can reduce ideal current for a given delivered power, but the complete branch design still determines voltage drop, power injection, connector loading and protected output limits.
View C5206 · 48V system guidance
Voltage selection
Do not select a fixture only by nominal voltage. Match the fixture, GC08 voltage, protected output architecture, cable gauge, connector rating, branch length, power-injection plan and applicable certification documents.
- 12V: C5204A platform.
- 24V: C5204B, C5205 and P23A platforms.
- 36V: C5204C platform.
- 48V: C5206 platform.
Installation and system compatibility
Each fixture must use its matched mounting profile and approved wiring configuration. The GC08 capacity does not by itself define the allowable load of each protected output. Final fixture count, branch layout, cable type, connector rating, power injection and control firmware should be reviewed against the selected model.
For professional installations, start with the installation and wiring guidance, then review voltage-drop planning and power-injection planning.
Need help selecting a system?
For a project review, provide the illuminated roofline length, unlit cable gaps, preferred spacing, fixture choice, branch layout, installation environment and destination. G&D SMART can then match the fixture, profile, controller, wiring and documentation to the project.
Discuss Your Project · Explore OEM/ODM Solutions
Published specifications are planning references. Confirm the exact supplied revision, product marking, wiring drawing and applicable certification documents before final approval or installation.
Frequently Asked Questions
Which G&D SMART fixture should I choose for a 12V, 24V, 36V or 48V system?
C5204 covers 12V, 24V and 36V variants; C5205 and P23A are 24V platforms; C5206 is the 48V platform. The final choice should also match the GC08 voltage, wiring, connector, branch layout and applicable certification documents.
What is the main difference between C5204, C5205 and P23A?
C5204 is the multi-voltage, multi-spacing platform in this comparison. C5205 is a compact 24V, 9-inch RGBW platform. P23A is a smaller 24V, 9-inch platform with published SPI and TTL support that must be confirmed against the supplied revision.
Does IP67 mean the complete lighting system is suitable for Wet Location?
No. An IP67 fixture rating does not by itself establish Wet Location suitability for the complete installed system. Confirm the exact fixture marking, cable, connector, control box, certification scope and installation instructions.
Is the maximum number of lights determined by the fixture power alone?
No. Fixture power is only one input. Branch length, wire gauge, connector rating, voltage drop, power injection, controller output protection and the actual worst-case operating mode must also be evaluated.
G&D SMART within the SHLED Group
G&D SMART is the SHLED Group business focused on permanent outdoor roofline lighting, control systems, installation components and related OEM/ODM programs. SHLED provides the broader group engineering and manufacturing resources. This website uses G&D SMART as the product and solution brand for the permanent outdoor lighting business.
Choose by Project Requirement
Use the project requirement first, then confirm the voltage, fixture format and control architecture. This matrix is a selection guide, not a substitute for the approved electrical and certification design.
| Project requirement | Starting platform | Why | Next check |
|---|---|---|---|
| Need one fixture family across 12V, 24V and 36V programs | C5204 | Multi-voltage platform with multiple spacing options | Confirm the exact voltage variant, spacing, wiring and GC08 configuration |
| Standard 24V project with a compact 9-inch fixture | C5205 | 24V RGBW, 9-inch platform with compact fixture format | Confirm branch length, cable gauge, connector rating and protected output load |
| Prioritize the smallest fixture appearance | P23A | 24V, 9-inch platform with the smallest fixture diameter in this comparison | Confirm supplied revision, protocol/firmware mapping and installation components |
| Prefer a 48V system architecture | C5206 | Dedicated 48V platform | Confirm 48V controller, 16AWG/M12B configuration, branch voltage drop and power-injection plan |
What Should Be Compared Before Ordering?
- Fixture: diameter, spacing, RGB/RGBW configuration and exact revision.
- Voltage: 12V, 24V, 36V or 48V must match the complete system.
- Power: use the actual worst-case operating mode, not only nominal fixture wattage.
- Wiring: cable gauge, outdoor rating, connector rating and branch length.
- Control: GC08 output protection, SPI topology and firmware limitations.
- Certification: verify the exact combination of fixture, cable, controller and installation environment.
Recommendation Evidence by Project Scenario
These are starting-point recommendations for system selection. They are not a guaranteed maximum run or a substitute for the final load, voltage-drop, wiring and certification review.
100 ft roofline
Starting point: C5204A for 12V, or C5204B / C5205 / P23A for 24V. For a 48V architecture, evaluate C5206. The deciding factors are fixture format, voltage platform, spacing and the approved controller configuration.
Evidence to verify: fixture count × actual fixture power, cable gauge, branch length, connector rating, GC08 output protection and end-of-branch voltage.
200 ft roofline
Starting point: prioritize 24V or 36V/48V system architectures when they fit the project requirements, because current for a given power is lower at higher voltage. Do not treat roofline length as a guaranteed single-branch capability.
Evidence to verify: branch topology, voltage drop, power-injection points, controller output limits and actual worst-case operating mode.
300 ft roofline
Starting point: evaluate a multi-output GC08 architecture rather than selecting a fixture from length alone. C5204B / C5205 / P23A are 24V options; C5204C is 36V; C5206 is 48V.
Evidence to verify: divide the roofline into protected branches, calculate each branch load and voltage drop, then confirm the controller, wiring and signal topology.
400 ft roofline
Starting point: treat the project as a system design rather than a single 400-ft string. Consider multiple GC08 outputs and, where required, multiple control boxes or planned power-injection points.
Evidence to verify: total system load, branch-level current, cable and connector ratings, controller capacity, synchronization/control architecture and certification scope.
How the Recommendation Is Determined
- Project length — establish illuminated length and unlit gaps separately.
- Fixture choice — select diameter, spacing and RGB/RGBW configuration.
- Voltage — match the fixture and controller voltage.
- Load — calculate actual worst-case fixture load.
- Branch design — determine cable gauge, connector rating, branch length and power injection.
- Control — confirm GC08 output protection, SPI topology and required firmware.
- Certification — verify the exact fixture, cable, controller and installation-environment combination.
Plan your next step with G&D SMART.
Share your application, target market and system requirements.