Skip to content
Permanent outdoor lighting systems • Hardware, control boxes & OEM/ODM
Discuss Your Project
Menu
G&D SMART GC08 configurable permanent outdoor lighting control box, angled white-background product view
Additional product images & supporting documents
G&D SMART GC08 configurable permanent outdoor lighting control box, top white-background product view G&D SMART GC08 permanent outdoor lighting control box exterior front view G&D SMART GC08 permanent outdoor lighting control box exterior top view G&D SMART GC08 permanent outdoor lighting control box exterior side view G&D SMART GC08 control box internal hardware layout, top view G&D SMART GC08 control box internal hardware layout, angled view G&D SMART GC08 control box cable entry and cooling fan detail G&D SMART GC08 controller board and protected output hardware close-up G&D SMART GC08 control box enclosure top view G&D SMART lighting App scene library example for permanent lighting control G&D SMART reliability validation framework for outdoor lighting systems

G&D SMART / Professional product evaluation

Controllers & Control Boxes

GC08 Configurable Permanent Lighting Control Box

Evaluate this product as part of a complete permanent outdoor lighting system, branded range or OEM/ODM program.

B2B / OEM product. Pricing depends on model, voltage, quantity and system configuration. Request a quote for current project pricing.

Your preferred configuration

Optional preferences for your inquiry. Compatibility and availability are confirmed during review.

Product information

GC08 is the configurable hardware hub of the G&D SMART permanent outdoor lighting control system. It combines power distribution, protected outputs and controller integration with a software route that can use the G&D SMART App, a private-label brand App or a qualified compatible control platform.

SYSTEM MATCHING · QUICK ANSWER

Which G&D SMART Fixture Matches Each GC08 Voltage?

GC08 output voltage Matching G&D SMART fixture family Key selection check
12V C5204A Confirm 12V fixture, branch plan and approved harness
24V C5204B / C5205 / P23A Confirm exact fixture revision, connector pinout and firmware
36V C5204C Confirm 18AWG standard C5204 wiring route and M12B 10A configuration
48V C5206 Confirm 16AWG standard wiring, M12B 10A and 48V-specific signal accessories

Do not mix output voltages: the GC08 output voltage must match the selected fixture variant. A matching voltage alone does not establish full compatibility; verify connector pinout, data protocol, cable assembly, branch current, voltage drop, firmware and model-specific certification.

GC08 hardware revisions: the standard four-protected-output GC08 and GC08 Pro six-SPI-port design are different configurations. Confirm the exact model/revision before applying port counts, individual output ratings or total capacity rules.

Compare C5204 / C5205 / P23A / C5206 · Voltage architecture guide · Wiring guide

One control-box family for 12V / 24V / 36V / 48V systems

Output voltage 350W option 600W option
12V GC08-12-350 GC08-12-600
24V GC08-24-350 GC08-24-600
36V GC08-36-350 GC08-36-600
48V GC08-48-350 GC08-48-600

Four protected output channels

The current GC08 architecture is designed around 4 protected DC outputs, up to 150W per output where supported by the selected model configuration. This makes it possible to plan separate roofline branches and keep output protection inside the control-box architecture rather than treating the enclosure as one uncontrolled high-power output.

  • 350W version: the sum of all active outputs remains limited by the approved 350W total platform capacity and project configuration.
  • 600W version: designed for higher total system loading, while each branch still follows its approved output, cable and protection limits.
  • Branch design must also respect fixture load, connector rating, cable gauge, voltage drop and the exact installed system.

4 × 150W does not mean a 350W box can deliver 600W. Individual-output architecture and total box capacity are separate limits.

GC08 is part of a complete control platform

System layer G&D SMART route Project value
Control hardware GC08 12V / 24V / 36V / 48V; 350W / 600W One configurable control-box family
Embedded / firmware Controller logic, fixture protocol and hardware-specific functions Hardware and software can be developed together
Mobile App G&D SMART App Supported route for professional installers
Private-label App Brand-specific App program using the in-house software foundation Regional brands can create their own customer-facing software identity
Cloud / SaaS Project-specific cloud and installer-management architecture Supports long-term brand and installer workflows where included

For professional installers

GC08 can be supplied as the hardware platform behind the G&D SMART App. This gives installers a coordinated route for fixtures, controller, firmware and App support instead of combining unrelated hardware and software from different suppliers.

Explore the G&D SMART App & Installer Platform

Installer-facing App functions relevant to GC08

The G&D SMART App implementation baseline includes several functions that are directly relevant to controller setup and service. Availability must still be confirmed against the selected GC08/controller hardware and firmware revision.

  • Wi-Fi device onboarding and Bluetooth device onboarding
  • Bluetooth direct control
  • Device light-count setting
  • Dual-SPI direction setting
  • Zone editing and control
  • Firmware OTA upgrade
  • Device information and Wi-Fi change
  • Power-off memory and device maintenance functions

Review the complete 32-function App baseline

For regional brands and OEM/ODM customers

GC08 can also be used as the hardware base for a private-label control program. G&D SMART / SHLED can coordinate controller hardware, firmware, App UI, cloud/SaaS requirements and ongoing software revisions within the agreed project scope.

  • Brand / private-label product configuration
  • Brand-specific App identity and approved UI scope
  • Firmware and hardware mapping
  • App-store release planning under the agreed brand identity or account
  • Continued platform upgrades and compatibility review under the agreed maintenance plan

Private Label App & IoT Development · OEM/ODM Solutions

SHLED / G&D SMART in-house IoT development

SHLED, G&D SMART's parent company, has its own IoT development resources supporting embedded electronics, firmware, mobile UI/App, cloud services and SaaS development for smart outdoor lighting systems. This allows GC08 development to be coordinated with fixture behavior, installation workflow and software instead of treating the controller as an isolated box.

System matching

  • 12V: match to approved 12V fixture, cable and M12 connector configuration.
  • 24V: match to approved 24V fixture, cable and M12 connector configuration.
  • 36V: match to approved 36V fixture, 18AWG standard wiring route and project branch plan.
  • 48V: match to approved 48V fixture, 16AWG standard wiring route and project branch plan.

Use the exact approved M12B / M12J harness, current rating, pinout and installation-location configuration defined for the selected voltage and product revision.

Protection, monitoring and engineering options

Depending on the selected hardware revision and project scope, the control-box program can include branch protection, surge-protection design and system monitoring functions. Exact current, voltage, temperature, network-status and diagnostic functions must be confirmed in the supplied hardware/firmware specification rather than assumed from the enclosure name alone.

Certification and documentation

G&D SMART can support model-specific compliance planning and UL certification programs for qualified control-box projects. Do not interpret GC08, 350W / 600W, or the enclosure appearance as a blanket UL or Class 2 claim. The applicable certification scope, power source, individual-output architecture, environmental rating and final wiring are confirmed by the supplied model documentation.

Class 2 & control-box documentation · Certification evidence

Compatible software routes remain available

The G&D SMART platform is the preferred route when a customer wants coordinated hardware/software development and long-term roadmap control. For projects with an established ecosystem, WLED-compatible, Surplife, Tuya-based or XLights-oriented routes can also be evaluated where the selected controller, firmware and fixture protocol support them.

Compare Compatible Control Platforms

Information required for a GC08 project review

  • System voltage and fixture model
  • Fixture count, branch layout and expected maximum load
  • 350W / 600W target and required output architecture
  • Cable gauge, connector and installation-environment requirements
  • G&D SMART App, private-label App or compatible control-platform route
  • Brand customization, certification and documentation requirements
  • Target market, estimated volume and planned launch schedule

Request a GC08 control-system review

Supported LED driver IC platforms

The G&D SMART GC08 control box supports lighting systems using UCS2904C, UCS7604 and SM18115, with the matching fixture design and controller firmware configuration.

  • UCS2904C: four-channel RGBW driver platform.
  • UCS7604: four-channel RGBW with high-grayscale and dual-channel signal fault-tolerant features when the selected GC08 hardware and firmware configuration provides the required DO/FDO routing.
  • SM18115: five-channel RGBWY driver platform for RGB plus two independently controlled white channels, subject to the matching fixture and firmware mapping.

IC support does not mean every feature is enabled in every GC08 model or firmware revision. Confirm the selected driver IC, fixture voltage, data format, channel mapping and firmware version for the project.


GC08 Port-Level and Total-Capacity Rules

The published GC08 platform currently describes 4 protected DC output channels, with up to 150W per output where supported by the selected model configuration. The 350W/600W enclosure rating and each protected output rating are independent constraints.

GC08 model Total nameplate 80% planning load Protected outputs Per-output published ceiling
350W 350W 280W 4 Up to 150W, configuration-dependent
600W 600W 480W 4 Up to 150W, configuration-dependent

Six-output GC08: do not assume six protected outputs or reuse the 150W/output value until the six-output hardware revision and its protection/certification documentation are verified.

Two independent sizing checks

  1. Enclosure total: sum of all active outputs must remain within the selected model's total capacity and G&D SMART 80% planning target.
  2. Each output: each branch must independently remain within the exact output's voltage, current, wattage, protection, connector, cable and voltage-drop limits.

For example, 4 × 150W is a theoretical sum of output ceilings, not permission for a 350W GC08 to deliver 600W. A 350W unit remains subject to its 350W nameplate and 280W planning target; a 600W unit remains subject to 600W nameplate and 480W planning target.

Recommended allocation approach

Allocate branches so that both conditions are met: per-output limits are respected and the sum of all active branch loads per controller stays within its recommended planning capacity. Where connector current is lower than the output ceiling, the connector becomes the limiting component.

Design hold point

Confirm exact voltage-specific model, board revision, port protection trip/current, connector pinout/rating, power supply, thermal limits and certification scope before releasing a wiring BOM. No parallel connection of protected outputs or separate supplies unless explicitly approved by the GC08 design.


GC08 Power Outputs vs. SPI Data Channels

Do not treat protected DC power outputs and SPI data channels as the same thing. The currently published GC08 product architecture describes 4 protected DC output channels, with up to 150W per output where supported by the selected model configuration. SPI data-channel count, data routing and supported pixel protocols are a separate controller/firmware specification and must be confirmed for the exact hardware revision.

A six-SPI-channel controller revision does not automatically mean six independently protected power outputs. Conversely, four protected power outputs do not by themselves establish the number of independently addressable SPI data paths.

400ft / 9-inch allocation using the published 4-output GC08 architecture

Planning assumptions: approximately 533 fixtures. C5204C/C5205 use 0.96W per fixture; C5206 uses 1.00W per fixture. Each GC08 has 4 protected DC outputs. The per-output 150W figure applies only where supported by the exact selected configuration. GC08 total recommended planning loads are 280W (350W version) and 480W (600W version).

Fixture Controller setup Output allocation Load / output Current / output Connector reference
C5204C / 36V 2 × GC08-36-350 4 active outputs total; 2 per controller ~127.7W (133 fixtures) ~3.55A M12B 10A; confirm harness
C5205 / 24V 2 × GC08-24-350 8 active outputs total; 4 per controller ~63.4–64.3W (66–67 fixtures) ~2.64–2.68A M12B 5A reference; confirm harness
C5206 / 48V 2 × GC08-48-600 4 active outputs total; 2 per controller ~133–134W (133–134 fixtures) ~2.77–2.79A M12B 10A; confirm harness

Why these allocations differ

  • C5204C: each 350W controller carries about 255.8W across two outputs, below its 280W planning target; each output is about 127.7W, below 150W where supported.
  • C5205: 4 outputs per controller are used to keep each 24V branch current below the 5A M12B reference. Each controller carries about 255.8W across four outputs.
  • C5206: each 600W controller carries about 266.5W across two outputs, below its 480W planning target; each output is about 133–134W.

Mandatory configuration checks

  1. Verify the exact voltage-specific GC08 model and hardware revision.
  2. Verify 4 protected DC outputs and whether the up-to-150W/output capability applies to that exact version.
  3. Verify output protection current/trip behavior and whether output power is continuous or conditional.
  4. Verify connector part number, pinout and current rating.
  5. Verify SPI data-channel count, protocol, data routing and firmware mapping separately.
  6. Calculate distributed-load voltage drop for every physical branch.
  7. Verify total controller load against 280W/480W planning targets and the approved certification scope.

Six-output hardware: do not publish a six-protected-power-output matrix or assign 100W/150W per port until the exact six-output board drawing, output protection specification and certification documentation are available.


GC08 Power Distribution and SPI Data Architecture

GC08 must be specified as two coordinated but independent subsystems: protected DC power distribution and SPI data/control routing. The count of power outputs must never be inferred from the count of SPI data channels.

Current published power architecture

Feature Current published specification Design rule
Protected DC outputs 4 channels Each output is independently protected, subject to exact hardware revision
Maximum per output Up to 150W where supported by selected configuration Verify output voltage/current protection, connector and certification
350W total platform 350W nameplate / 280W recommended planning load Sum of all active outputs must remain within both limits
600W total platform 600W nameplate / 480W recommended planning load Sum of all active outputs must remain within both limits
SPI data channels Confirm by board revision and firmware Data channel count is not the DC power-output count

Current supported driver IC / pixel protocol references

IC Channel architecture Resolution / feature GC08 implementation condition
UCS2904C 4-channel RGBW 8-bit class Confirm timing, channel order, pixel count and firmware profile
UCS7604 RGB or RGBW modes 16-bit; configurable current control; redundant data features per supported topology Confirm DO/FDO routing, firmware and selected operating mode
SM18115 5-channel RGB plus two white channels per current product description (RGBWY) 5-channel control Confirm whether firmware mapping supports intended RGBCW/CW+WW behavior; do not assume all 5-channel fixtures are equivalent

RGBW means R/G/B + one dedicated white channel. RGBCW normally means R/G/B + cool white + warm white (five independently controlled channels). Confirm the actual IC channel mapping: a five-channel RGBWY designation must not automatically be relabeled RGBCW without verifying which two white channels are implemented.

4 protected power outputs × SPI data routing

One SPI data channel may control a data chain that receives power from one or more separately protected branches only where the fixture topology and power-feed design explicitly support it. Conversely, one protected DC output may feed fixtures whose data is routed on a separate SPI channel, if the approved harness and system design permit it. The wiring drawing must identify DC+, DC−, DATA, any backup data line, ground reference and connector pinout.

Six-SPI hardware revision

A future or project-specific six-SPI version should be documented separately from the currently published four-protected-output architecture. Before release, record the board revision, number of physical data outputs, supported protocols, maximum pixels/data refresh per channel, output voltage/current protection, connector allocation, synchronization behavior and UL/cUL certification scope. Do not describe it as six independent protected power outputs unless the hardware design confirms that fact.

System Designer configuration checks

  1. Select fixture SKU and actual IC.
  2. Select RGB / RGBW / RGBCW channel map and bit depth.
  3. Select SPI data output and pixel protocol profile.
  4. Separately assign each physical DC branch to a protected GC08 power output.
  5. Calculate branch watts, amps, connector loading and distributed voltage drop.
  6. Verify total GC08 load against 280W/480W planning capacity.
  7. Verify exact hardware revision, firmware and certification documents.

GC08 Hardware Configuration Matrix

This matrix separates confirmed product-family options from proposed engineering configurations. A configuration name is not a released specification until the PCB revision, wiring diagram, protection design, firmware and certification records are approved.

Published GC08 voltage and total-capacity variants

DC voltage 350W SKU 600W SKU 80% planning load
12V GC08-12-350 GC08-12-600 280W / 480W
24V GC08-24-350 GC08-24-600 280W / 480W
36V GC08-36-350 GC08-36-600 280W / 480W
48V GC08-48-350 GC08-48-600 280W / 480W

Power-output and SPI architecture

Architecture Protected DC outputs SPI data outputs Status Release condition
Current published GC08 family 4 Confirm exact board revision Published power architecture Confirm exact model wiring and firmware
4P-4SPI Standard 4 proposed 4 proposed Proposed configuration, not a separately verified SKU PCB/IO map, protocol tests, output protection and certification review
4P-6SPI Pro 4 proposed 6 proposed Proposed configuration, not a separately verified SKU PCB/IO map, GPIO availability, data timing, firmware, thermal and certification review

4P means four protected DC power outputs. SPI count describes independent data paths only. Do not imply that a six-SPI controller has six protected power outputs.

Power limits to keep independent

  • 350W model: 350W nameplate, 280W recommended system-planning load.
  • 600W model: 600W nameplate, 480W recommended system-planning load.
  • Published up-to-150W per protected output applies only where supported by the exact model configuration.
  • The sum of active outputs must remain within the enclosure total limit and the recommended planning load.
  • Each output must independently satisfy its protection current, connector, wire, branch voltage-drop and certification limits.

Required hardware release matrix

Item Required evidence
PCB revision Approved schematic, PCB and BOM revision
Power outputs Output count, voltage, continuous current, wattage, protection threshold and trip behavior
SPI outputs Physical output count, GPIO mapping, supported IC protocols, data rate, refresh/pixel limits and signal topology
LED driver IC UCS2904C / UCS7604 / SM18115 or other exact part, channel map and validated bit depth
Connectors Part number, pinout, current rating, cable gauge and environmental rating
Firmware Protocol profile, pixel count, channel order, synchronization and OTA version
Thermal/protection Worst-case load test, temperature rise, overload/short-circuit behavior and recovery
Certification Exact model scope, supply, output configuration, cable/fixture combinations and installation location

System Designer rule

The configurator must first select a released GC08 SKU and voltage/capacity variant. It must then allocate physical branches to protected DC outputs and map data chains to supported SPI outputs independently. If a requested 6-SPI or other configuration has not been released and validated, show Engineering Review Required — proposed hardware configuration, not an available standard product.


GC08 PCB-Level Engineering Specification — Design Proposal

Status: engineering proposal, not a released PCB specification. Final GPIO assignments, output circuits, protection thresholds, thermal limits and certification scope require schematic/PCB review and validation testing.

1. System architecture

Subsystem Proposed definition Release evidence
MCU ESP32-S3 module; external Wi-Fi antenna option per enclosure/product variant Exact module, flash/PSRAM, antenna path and RF test
Power distribution 4 independently protected DC outputs in current published architecture Per-output schematic, current limit, trip/recovery and load test
Pixel data Target 6 independent pixel-data outputs for Pro revision Waveform timing, DMA/RMT/parallel-output implementation, concurrency and refresh tests
Monitoring Per-output voltage/current/power and controller temperature monitoring as selected hardware supports Sensor accuracy, calibration, fault thresholds and firmware telemetry
Network/control Wi-Fi, Bluetooth, Ethernet/RJ45 where specified RF, EMC, ESD, surge and network coexistence tests

2. Critical ESP32-S3 design clarification

ESP32-S3 exposes two general-purpose SPI controllers (SPI2 and SPI3); SPI0/SPI1 are used for flash/PSRAM access. Therefore, do not design six independent pixel outputs by assuming six independent hardware SPI hosts. The six-output target should be implemented and benchmarked using a suitable parallel pixel-output architecture (for example, RMT/DMA or a parallel peripheral/GDMA approach) with independent timing/state per output, subject to the selected ESP-IDF release and protocol waveform. GPIO Matrix routing is available, but pin allocation must avoid flash/PSRAM, strapping and reserved pins.

Also, UCS2904 is a one-wire, data-only pixel protocol rather than conventional clocked SPI. In product documentation, use pixel-data output / independent data channel where appropriate, and reserve “SPI” for actual SPI buses or the established product-market terminology with an explicit protocol note.

3. Pixel IC / protocol profiles

IC profile Channel model Data / grayscale Engineering requirement
UCS2904C RGBW, 4 channels 800kbps data-only; 8-bit/channel reference Validate pulse timing, reset/latch time, channel order, maximum chain length and refresh rate
UCS7604 Confirm exact RGB/RGBW mode from datasheet/revision High-grayscale/16-bit feature as supported by exact IC Validate DO/FDO topology, bit depth, timing and firmware mapping
SM18115 Five-channel family; confirm exact channel labels and part revision Use exact datasheet bit depth/protocol Confirm whether implementation is RGB + CW + WW before calling it RGBCW

4. Proposed signal-to-power separation

Define separate identifiers in schematic, firmware and installation drawings: DATA_CH1–DATA_CH6 for pixel data; PWR_OUT1–PWR_OUT4 for protected DC outputs. Each fixture chain must map to one data channel and one or more approved power branches. A data channel may span multiple power branches only where the approved fixture harness and power-injection topology support it. A power branch may not be assumed to equal one data chain.

5. PCB design blocks

  • MCU module and boot/programming interface
  • Pixel-data output drivers/level shifting and output protection
  • Four protected DC output stages with independent current sensing
  • Input voltage/current sensing and power supply monitoring
  • Temperature sensing at power/thermal hotspots
  • Ethernet/RJ45 magnetics and ESD protection where included
  • Wi-Fi/Bluetooth antenna keep-out and RF layout
  • Surge/ESD/transient protection and grounding strategy
  • Fan control and thermal fault response where fitted

6. Firmware architecture

  1. Hardware capability descriptor: board revision, power-output count, data-output count and sensor availability.
  2. Per-channel protocol profile: IC type, data rate, reset timing, bit depth, channel order, pixel count and direction.
  3. Independent data-channel buffers and deterministic refresh scheduling.
  4. Power-output mapping kept separate from pixel-data mapping.
  5. Fault handling: overcurrent, short circuit, undervoltage, overtemperature and sensor failure.
  6. OTA rollback and persistence of output limits after reset/update.

7. Validation gates before release

Test Acceptance evidence
Six-channel concurrency All six data outputs refresh simultaneously at target pixel counts without frame corruption
Protocol compatibility UCS2904C / UCS7604 / SM18115 tested on their validated profiles
Power outputs Each output protection trip, recovery and sustained load documented
Monitoring Voltage/current/power readings calibrated against reference instruments
Thermal Worst-case enclosure and ambient-temperature load test
EMC/ESD/surge Pre-compliance and formal test reports
Safety/certification Exact PCB revision, PSU, output wiring, enclosure and intended location within evaluated scope

Release rule: do not advertise 6 independent data channels, 4 protected power outputs, per-port wattage or supported IC combinations as universally available until the exact board revision and firmware have passed the corresponding validation gates.


GC08 Pro Schematic Block Diagram and I/O Resource Plan

Status: preliminary design proposal for schematic review. This is not a final GPIO pin assignment, released schematic, production BOM or certification-approved design. Exact pin numbers must be assigned only after the selected ESP32-S3 module, flash/PSRAM configuration, Ethernet interface, USB/JTAG/debug needs and PCB routing constraints are frozen.

1. Proposed hardware block diagram

AC INPUT
  │
  ├── Approved AC/DC Power Supply (voltage-specific 12/24/36/48V)
  │       │
  │       ├── Main DC Bus / Input Protection / Surge Protection
  │       │       │
  │       │       ├── Protected DC Output 1 ─ Current/Voltage Sense ─ M12 Output 1
  │       │       ├── Protected DC Output 2 ─ Current/Voltage Sense ─ M12 Output 2
  │       │       ├── Protected DC Output 3 ─ Current/Voltage Sense ─ M12 Output 3
  │       │       └── Protected DC Output 4 ─ Current/Voltage Sense ─ M12 Output 4
  │       │
  │       └── DC/DC Rails (MCU / logic / sensor / Ethernet)
  │
  └── ESP32-S3 Module
          ├── Pixel Data Engine ─ Level Shift / Line Driver ─ DATA 1..6
          ├── I2C Sensor Bus ─ Current/Voltage/Temperature Monitors
          ├── Ethernet MAC/PHY + RJ45 (if included)
          ├── Wi-Fi / Bluetooth + Antenna
          ├── Fan / Status / Fault Inputs
          └── USB / UART / JTAG / Reset / Boot

2. I/O resource allocation — signal groups, not pin numbers

Resource group Count Proposed function Design notes
PIXEL_DATA[1..6] 6 outputs Independent one-wire pixel data channels Evaluate LCD_CAM parallel DMA output first; evaluate RMT/DMA or external logic as fallback. Do not call these six hardware SPI hosts.
POWER_EN[1..4] 4 outputs Enable/disable protected DC output stages Hardware default-off on reset; fail-safe pull-downs.
POWER_FAULT[1..4] 4 inputs Per-output fault/overcurrent status Hardware protection must operate independently of firmware.
SENSE_BUS 1 bus I2C/SPI sensor interface for current, voltage and temperature monitors Choose monitor ICs and bus isolation/addressing in schematic.
THERMAL / FAN As required Temperature inputs and fan PWM/tach Define thermal thresholds and safe shutdown behavior.
ETHERNET As required RJ45 network interface Freeze PHY/interface choice before GPIO allocation; include magnetics/ESD.
DEBUG / SERVICE As required USB, UART, JTAG, boot/reset Preserve production programming and field-service access.

3. Pixel output implementation recommendation

ESP32-S3 provides two general-purpose SPI hosts, SPI2 and SPI3; SPI0/SPI1 are used for flash/PSRAM access. For six independent one-wire pixel data outputs, do not allocate six SPI controllers. Evaluate the ESP32-S3 LCD_CAM parallel output with DMA as the primary synchronized multi-lane option, subject to waveform encoding, memory bandwidth, refresh timing and coexistence tests. Evaluate RMT/DMA for independent channels or a dedicated external pixel-output engine if LCD_CAM timing/resource contention is unsuitable. A final choice requires a six-channel simultaneous-load prototype.

4. Power output hardware rules

  • Four protected DC outputs are separate power paths, each with its own current limit/protection and sensing.
  • Each output stage should include a hardware-defined safe-off state, short-circuit/overcurrent response, fault reporting and controlled recovery.
  • Current sensing should be sized for the actual per-output maximum, accuracy and fault transient; voltage sensing should measure the branch/output under load.
  • Do not rely on ESP32 firmware as the only overcurrent or short-circuit protection.
  • Keep high-current return paths, analog sense grounds and MCU logic grounding under a reviewed PCB grounding/layout plan.

5. Proposed schematic sheets

  1. AC/DC power input, fuse, surge and EMI filtering
  2. Main DC bus and voltage-specific power supply interface
  3. Four protected DC output stages, current/voltage sensing and M12 connectors
  4. ESP32-S3 module, boot, reset, USB/UART/JTAG and memory
  5. Six-channel pixel data engine, level shifting and output connectors
  6. Ethernet/RJ45, Wi-Fi/Bluetooth antenna and ESD protection
  7. Temperature, fan, status LEDs and fault inputs

6. GPIO assignment release checklist

Before publishing GPIO numbers, freeze: exact ESP32-S3 module; flash/PSRAM mode and occupied pins; USB/JTAG use; Ethernet PHY and interface; LCD_CAM or RMT output method; I2C sensor addresses; fan/status/fault signal count; boot-strapping pins; reserved pins; and connector mapping. Then publish a pin table with GPIO number, signal name, direction, boot state, pull-up/down, voltage domain and test point.

7. Prototype validation gates

  • Six pixel outputs run simultaneously at the target protocol, refresh rate and maximum intended pixel count without data corruption.
  • Verify RGBW 8-bit and supported 16-bit profiles; verify five-channel RGBCW only with the exact IC/channel mapping.
  • Run all four power outputs at worst-case load; verify current/voltage measurement accuracy and hardware protection trip/recovery.
  • Test pixel-data integrity during output switching, Wi-Fi/Bluetooth activity, Ethernet traffic and OTA.
  • Run thermal, short-circuit, open-load, reverse-polarity where applicable, ESD, surge and EMC pre-compliance tests.
  • Freeze the production BOM, wiring diagram, firmware capability descriptor and certification scope against the same PCB revision.

Release guardrail: do not publish exact GPIO assignments, six-channel performance claims or per-port electrical limits until the selected schematic and prototype test report confirm them.


GC08 Pro — Six Integrated SPI / Power Output Ports

Updated design specification supplied by G&D SMART: GC08 Pro has six SPI output ports with corresponding per-port power capability allocation: four ports rated up to 100W each and two ports rated up to 300W each. The sum of the individual port ratings is 1,000W, but the controller's total system output is limited to 600W maximum. The ports are not intended to be fully loaded simultaneously.

Port rating vs. total system limit

Port group Port count Maximum rating per port Group rating sum
Standard ports 4 100W 400W
High-power ports 2 300W 600W
All six ports 6 Per-port limits above 1,000W arithmetic sum

System-wide maximum output: 600W. The 1,000W figure is only the arithmetic sum of independent port ratings; it is not the available combined power.

Recommended operating load

Parameter Power
GC08 Pro total maximum 600W
G&D SMART recommended 80% planning load 480W
Reserved margin to maximum 120W

For normal system planning, calculate the sum of all six active port loads and keep it at or below 480W. The 600W system-wide maximum is an absolute design ceiling, not the normal target. Each individual port must also remain within its own 100W or 300W rating and the applicable current, connector, cable, thermal and protection limits.

System Designer allocation rules

  1. Assign each fixture chain to one of the six SPI output ports.
  2. For ports 1–4, enforce a maximum of 100W per port.
  3. For ports 5–6, enforce a maximum of 300W per port.
  4. Sum all six port loads and enforce a 480W recommended planning target and 600W absolute system maximum.
  5. Calculate branch current from each port's actual voltage and load.
  6. Verify cable, connector, voltage drop, end voltage and power injection independently for each branch.
  7. Apply hardware protection and firmware limits so the aggregate system cannot exceed the approved 600W maximum; normal planning should target 480W.

Illustrative allocation example

Example: Port 1 = 80W, Port 2 = 80W, Port 3 = 80W, Port 4 = 80W, Port 5 = 80W, Port 6 = 80W. Total = 480W. Every port is below its individual rating and the system is at the recommended 80% planning load.

Another example: Port 1 = 100W, Port 2 = 100W, Port 3 = 100W, Port 4 = 100W, Port 5 = 100W, Port 6 = 100W. Total = 600W. This is at the system maximum, not the recommended operating target; do not use as the default design condition.

Hardware distinction

This six-port 4 × 100W + 2 × 300W architecture is the GC08 Pro specification. Do not apply it to the existing standard GC08 four-protected-output model unless that exact hardware revision is separately confirmed. The 350W GC08 standard version continues to use its own 350W nameplate / 280W recommended planning limits; the 600W standard version uses its own 600W / 480W limits.

Final release requires confirmation of per-port voltage range, current limits, protection trip/recovery, connector/pinout, thermal limits, simultaneous load behavior and certification scope for the GC08 Pro PCB revision.

Technical Documents for GC08 Control Box

Request the manual, wiring diagram and output specification matching the exact GC08 hardware revision (standard GC08 or GC08 Pro).

Published model specifications

Catalog references for technical evaluation. Confirm the current model specification and approved revision before project approval. Empty fields have not been confirmed.

Product series / familyGC08 Platform
Model numberGC08
Voltage options (V DC)12 / 24 / 36 / 48
Published power / capacity (W)350.0 / 600.0
Certification verification statusConfirm the model-specific certification record, product markings and scope for the supplied configuration before approval.
Verified wet / damp / dry ratingConfirm the project location rating against the model-specific listing, markings and installation instructions. IP rating alone does not establish wet/damp suitability.
Verified Class 2 statusConfirm Class 2 status against the selected power source, output architecture and model-specific documentation.
OEM / ODM scopeDiscuss fixture or enclosure branding, product revisions and the complete roofline-system bill of materials. Feasibility, minimum quantities and validation scope are confirmed in the quotation.

Model and configuration notes

GC08-12/24/36/48 with 350W or 600W capacity options. Capacity is not a per-output rating or a Class 2 claim. Final output architecture and certification are project-specific.

Specification source

Current published G&D SMART product reference. Confirm the current model-specific datasheet and approved revision before project approval.

Reference documents

Product catalog, credentials & technical documents

Plan the complete configuration

  • Fixture or component format, mounting and intended application.
  • Supply voltage, load and compatible control equipment where applicable.
  • Tracks, connectors, cable and installation accessories.
  • Current model-specific documentation and commercial terms.

Read the system planning guide.

WhatsApp · Talk to G&D SMART

Choose the right person for a quick conversation. WhatsApp opens with a ready-to-send message referencing this page.

WhatsApp opens your chat; please press Send to deliver the message.

Or send an email inquiry

Privacy policy · Project inquiry

Quick Inquiry

Tell us what you need. Our team will get back to you.

Detailed project inquiry