Online System Planning Tool
Enter roofline length, spacing, voltage, fixture wattage, extension cable length and wire gauge to estimate light quantity, branch load, voltage drop, last-light voltage, GC08 capacity and a preliminary BOM.
Plan the system in this order: choose voltage first, then fixture family, GC08 capacity, track and cable layout, and finally the required control-platform route.
GC08 is available in 350W and 600W versions for each voltage architecture.
350W vs 600W GC08 Control Box Guide
Confirm the selected roofline light, model-matched track, cable and connector family, signal accessory requirements and final branch layout as one project configuration.
Control platform, firmware and App capability should be confirmed against the final GC08 revision selected for the project.
Compare fixture models · Compare all six Installer Kits · Request a configuration review
CONTROLLER HARDWARE REVISION · SYSTEM DESIGN RULE
| Platform | Published architecture | Planning boundary |
|---|---|---|
| Standard GC08 | Four protected DC power outputs; 350W or 600W total-capacity versions. The product reference describes up to 150W per output where supported by the selected configuration. | Verify the exact voltage, total nameplate capacity, per-output protection and approved branch limit for the supplied model. Do not assume all four outputs can each deliver 150W simultaneously. |
| GC08 Pro | Six integrated SPI / power output ports: four ports rated up to 100W each and two ports rated up to 300W each; 600W maximum total system output. | The arithmetic sum of per-port ratings is 1,000W, but available combined output remains capped at 600W. Recommended planning target is 480W total, with every port also kept within its own rating. |
A power output count is not automatically an SPI data-channel count. Do not transfer the GC08 Pro six-port specification to the standard four-output GC08. Do not treat the sum of individual port ratings as the combined system capacity.
GC08 product and hardware specification · Capacity planning · Class 2 documentation
Use the recommended 80% operating target for controller-count planning: 350W GC08 = 280W and 600W GC08 = 480W. Divide the calculated total connected load by the applicable recommended planning capacity and round up. Then distribute the load across protected outputs and verify branch current, wiring, connectors, voltage drop, power injection and certification separately.
This planning layer combines roofline length, fixture spacing, estimated fixture count, baseline load, voltage strategy, GC08 quantity and branch planning. Fixture count = floor(length in feet × 12 ÷ spacing in inches). Baseline load = fixture count × 0.96W.
GC08 planning rule: 350W GC08 = 280W recommended operating capacity; 600W GC08 = 480W recommended operating capacity. Controller quantity is based on total planning load and then rounded up. This is not a certification limit.
| Length | Spacing | Lights | Load | Voltage direction | GC08 planning | Branch planning* |
|---|---|---|---|---|---|---|
| 100 ft | 6" | 200 | 192.0W | 24V / 36V | 1×350W (≤280W) | 2 |
| 100 ft | 8" | 150 | 144.0W | 24V / 36V | 1×350W (≤280W) | 2 |
| 100 ft | 9" | 133 | 127.7W | 24V / 36V | 1×350W (≤280W) | 2 |
| 100 ft | 10" | 120 | 115.2W | 24V / 36V | 1×350W (≤280W) | 1 |
| 100 ft | 12" | 100 | 96.0W | 24V / 36V | 1×350W (≤280W) | 1 |
| 100 ft | 14" | 85 | 81.6W | 24V / 36V | 1×350W (≤280W) | 1 |
| 100 ft | 16" | 75 | 72.0W | 24V / 36V | 1×350W (≤280W) | 1 |
| 100 ft | 18" | 66 | 63.4W | 24V / 36V | 1×350W (≤280W) | 1 |
| 200 ft | 6" | 400 | 384.0W | 24V / 36V / 48V | 1×600W (≤480W) | 4 |
| 200 ft | 8" | 300 | 288.0W | 24V / 36V / 48V | 1×600W (≤480W) | 3 |
| 200 ft | 9" | 266 | 255.4W | 24V / 36V / 48V | 1×350W (≤280W) | 3 |
| 200 ft | 10" | 240 | 230.4W | 24V / 36V / 48V | 1×350W (≤280W) | 2 |
| 200 ft | 12" | 200 | 192.0W | 24V / 36V / 48V | 1×350W (≤280W) | 2 |
| 200 ft | 14" | 171 | 164.2W | 24V / 36V / 48V | 1×350W (≤280W) | 2 |
| 200 ft | 16" | 150 | 144.0W | 24V / 36V / 48V | 1×350W (≤280W) | 2 |
| 200 ft | 18" | 133 | 127.7W | 24V / 36V / 48V | 1×350W (≤280W) | 2 |
| 300 ft | 6" | 600 | 576.0W | 36V / 48V | 2×600W | 3 |
| 300 ft | 8" | 450 | 432.0W | 36V / 48V | 1×600W (≤480W) | 4 |
| 300 ft | 9" | 400 | 384.0W | 36V / 48V | 1×600W (≤480W) | 4 |
| 300 ft | 10" | 360 | 345.6W | 36V / 48V | 1×600W (≤480W) | 3 |
| 300 ft | 12" | 300 | 288.0W | 36V / 48V | 1×600W (≤480W) | 3 |
| 300 ft | 14" | 257 | 246.7W | 36V / 48V | 1×350W (≤280W) | 3 |
| 300 ft | 16" | 225 | 216.0W | 36V / 48V | 1×350W (≤280W) | 2 |
| 300 ft | 18" | 200 | 192.0W | 36V / 48V | 1×350W (≤280W) | 2 |
| 400 ft | 6" | 800 | 768.0W | 48V preferred | 2×600W | 4 |
| 400 ft | 8" | 600 | 576.0W | 48V preferred | 2×600W | 3 |
| 400 ft | 9" | 533 | 511.7W | 48V preferred | 2×600W | 3 |
| 400 ft | 10" | 480 | 460.8W | 48V preferred | 1×600W (≤480W) | 4 |
| 400 ft | 12" | 400 | 384.0W | 48V preferred | 1×600W (≤480W) | 4 |
| 400 ft | 14" | 342 | 328.3W | 48V preferred | 1×600W (≤480W) | 3 |
| 400 ft | 16" | 300 | 288.0W | 48V preferred | 1×600W (≤480W) | 3 |
| 400 ft | 18" | 266 | 255.4W | 48V preferred | 1×350W (≤280W) | 3 |
| 600 ft | 6" | 1200 | 1152.0W | 48V preferred | 3×600W | 5 |
| 600 ft | 8" | 900 | 864.0W | 48V preferred | 2×600W | 4 |
| 600 ft | 9" | 800 | 768.0W | 48V preferred | 2×600W | 4 |
| 600 ft | 10" | 720 | 691.2W | 48V preferred | 2×600W | 3 |
| 600 ft | 12" | 600 | 576.0W | 48V preferred | 2×600W | 3 |
| 600 ft | 14" | 514 | 493.4W | 48V preferred | 2×600W | 3 |
| 600 ft | 16" | 450 | 432.0W | 48V preferred | 1×600W (≤480W) | 4 |
| 600 ft | 18" | 400 | 384.0W | 48V preferred | 1×600W (≤480W) | 4 |
| 800 ft | 6" | 1600 | 1536.0W | 48V preferred | 4×600W | 7 |
| 800 ft | 8" | 1200 | 1152.0W | 48V preferred | 3×600W | 5 |
| 800 ft | 9" | 1066 | 1023.4W | 48V preferred | 3×600W | 5 |
| 800 ft | 10" | 960 | 921.6W | 48V preferred | 2×600W | 4 |
| 800 ft | 12" | 800 | 768.0W | 48V preferred | 2×600W | 4 |
| 800 ft | 14" | 685 | 657.6W | 48V preferred | 2×600W | 3 |
| 800 ft | 16" | 600 | 576.0W | 48V preferred | 2×600W | 3 |
| 800 ft | 18" | 533 | 511.7W | 48V preferred | 2×600W | 3 |
*Branch planning is a conservative system-planning aid, not a statement of the maximum permitted load per GC08 output. Final branch count and fixture distribution must follow the exact GC08 hardware, output protection, wire gauge, connector rating and certification requirements.
Do not promise a fixed maximum run length from this table alone. The same 400ft roofline can require very different architecture at 6-inch versus 18-inch spacing.
Length → spacing → fixture count → actual power → voltage → branch current → wire/connector → voltage drop → power injection → GC08 quantity → output distribution → certification.
Wire selection must be based on wire construction/listing → environment → system voltage → branch load → current → branch length → voltage drop → connector → certification. AWG alone does not determine outdoor suitability or a universal ampacity.
| Wire / Type | Environment | Primary role | 12/24/36/48V |
|---|---|---|---|
| UL2468 | Indoor / Dry; verify exact listing for other environments | Indoor electronics, controller/device wiring, protected connections | When exact listing/application permits |
| UL2464 | Indoor / Dry; verify exact listing | Multi-conductor control/equipment connections | When exact listing/application permits |
| SPT-1W | Outdoor / Wet when specifically listed | Permanent outdoor lighting, point-to-point, controller-to-first-light, branches | 12/24/36/48V |
| SPT-2W | Outdoor / Wet when specifically listed | Higher-load outdoor branches and power distribution | 12/24/36/48V |
| STOW | Outdoor / Wet / heavy-duty when specifically listed | Flood lights, landscape equipment, high-power distribution | Where exact system permits |
| AWG | Planning current reference | Preferred role |
|---|---|---|
| 24AWG | ≤2A | Short, low-power connections |
| 22AWG | ≤3A | Short point-to-point / low-power fixtures |
| 20AWG | ≤4A | Point-to-point branches / shorter runs |
| 18AWG | ≤6A | Outdoor permanent-light branches and controller-to-first-light |
| 16AWG | ≤10A | High-load branches, longer runs and power injection |
| 14AWG | >10A planning use where permitted | Large injection trunks and high-power landscape/flood applications |
These are G&D SMART planning references, not universal UL ampacity ratings. Final current capacity must be verified against the exact cable, insulation, temperature, installation method, connector, controller output and certification.
| Application | Preferred starting point |
|---|---|
| Indoor / Dry low-voltage | UL2468 / UL2464, exact listing verified |
| Outdoor point light → point light | 20AWG / 18AWG with an appropriate Wet-rated cable |
| Controller → first outdoor light | 18AWG; 16AWG for higher load/longer branch |
| Power injection | 16AWG; 14AWG for larger trunks when permitted |
| Outdoor flood / landscape | 16AWG / 14AWG; STOW where appropriate |
Do not recommend cable from AWG or roofline length alone. Identify environment, exact wire Type/listing, voltage, branch power, current and length; calculate voltage drop; verify connector/controller limits; then recommend AWG and whether to split the branch or add power injection.
You can begin with a customer need and an installation example. Use these three stages to organize your first conversation with G&D SMART.
For track-based permanent lighting, explore C5204 and C5205. For landscape projects, start with the fixture type: spot, pathway, flood or wall wash.
Agree the light module, mounting, control box and cables needed for a small demonstration. Confirm the sample contents and commercial terms before ordering.
Evaluate assembly, light effect, controls and service access. Record the approved parts and wiring plan before repeating the configuration across more projects.
Share your application, target market and system requirements.