Permanent Outdoor Lighting Calculator

G&D Smart Design Tool

Permanent Outdoor Lighting Calculator

Plan each signal branch separately, then let the calculator decide whether the project needs power injection or additional GC08 control capacity.

1. Project

2. Electrical

3. Distance

Additional Extension Segments
Assign each extension segment to a branch and enter its position and length.
Any single light-to-light extension segment over 19.7 ft (6 m) requires a signal-amplifier review.

4. Signal Branches

Send This Project to G&D Smart

The calculated system summary will be attached automatically.

Design Rules Used by This Calculator

Wire defaults: 12V/24V → 20 AWG; 36V/48V → 18 AWG. Users can manually choose 20/18/16 AWG.

Recommended current guidelines: 20 AWG ≤ 4A; 18 AWG ≤ 6A; 16 AWG ≤ 10A.

Minimum last-light voltage: 12V ≥ 9V; 24V ≥ 18V; 36V ≥ 24V; 48V ≥ 24V.

GC08: 4 standard output ports, maximum 150W per standard output. 350W box planned usable load ≤280W; 600W box planned usable load ≤480W. Each GC08 also has 2 auxiliary power-injection connections.

Decision logic: branch voltage/current problems use auxiliary power injection first when the selected GC08 still has planned total-power capacity. A larger/additional GC08 is recommended only when total fixture load exceeds the current GC08 planned usable capacity, or when the requested branch architecture cannot be supported.

Plan your next step with G&D SMART.

Share your application, target market and system requirements.

WhatsApp · Talk to G&D SMART

Choose the right person for a quick conversation. WhatsApp opens with a ready-to-send message referencing this page.

WhatsApp opens your chat; please press Send to deliver the message.

Or send an email inquiry

Privacy policy · Project inquiry

Quick Inquiry

Tell us what you need. Our team will get back to you.

Detailed project inquiry