Skip to content
Permanent outdoor lighting systems • Hardware, control boxes & OEM/ODM
Discuss Your Project
Menu
C5206 48V permanent outdoor roofline light by G&D SMART

G&D SMART / Professional product evaluation

Permanent Outdoor Lights

C5206 48V Permanent Outdoor Lights

Evaluate this product as part of a complete permanent outdoor lighting system, branded range or OEM/ODM program.

SKU: C5206

B2B / OEM product. Pricing depends on model, voltage, quantity and system configuration. Request a quote for current project pricing.

Product information

C5206 is the 48V fixture platform for professional permanent outdoor lighting. Evaluate the light together with its matched GC08 48V configuration, protected power outputs, mounting, cable plan and control software.

C5206 · MODEL SELECTION

When Does a 48V C5206 Roofline System Make Sense?

C5206 is the dedicated 48V RGBW SPI roofline fixture platform with 9-inch spacing and a published 30 × 16mm body size. Select it only with a matched 48V GC08 architecture and approved branch, power and signal design.

Published power: 1.00W per module. Standard wiring is UL2468 16AWG with M12B 10A. The current product record describes Dry / Damp configurations; do not assume Wet suitability or a model-specific certification without the applicable record and markings.

GC08 controller compatibility · Compare all four fixture platforms · 48V system guide · Request a C5206 project review

Key specifications

  • Voltage: DC48V
  • Power: 1.00W per module according to the published C5206 specification. This is a separate model reference; the C5204 maximum mixed-white power definition is not automatically applied to C5206.
  • Light source: 5050 RGBW with dedicated 3000K white
  • Control: SPI
  • Spacing: 9 inch
  • Standard string: 5 pieces
  • Dimensions: 30mm diameter × 16mm height
  • Shell: 945U PC, transparent
  • Beam angle: 120°
  • Module IP rating: IP67; this alone does not establish the complete installation's location rating
  • Operating temperature: -20 to 60°C
  • Published lifespan: at least 50,000 hours
  • Flame retardant: UL94-V0
  • UV resistance: UV-5
  • Standard wire: UL2468 16AWG
  • Standard connector: M12B 10A version
  • Standard configuration: Dry / Damp only where permitted by the finished-product marking and installation instructions; not a Wet-location offering
  • Custom cable and connector option: SPT-2W 16AWG + M12J 10A, following the current Damp / Dry project route
  • Certification status: request the model-specific record, product marking and scope for the exact supplied C5206 configuration

Power-injection planning at 9-inch spacing

350 modules: 262.5ft / 80.01m nominal coverage, 350W calculated fixture load and 7.29A ideal current. The current equals approximately 72.9% of the M12B 10A connector rating. This is a planning reference, not a verified maximum single-ended run.

Coverage is module count × 9in and excludes lead-in cable and unlit gaps; first-to-last centers span one fewer interval. P/V calculations exclude circuit losses. Verify source current, end voltage, wire loading, connector temperature and the protected-output design. A 350W lamp load is not approval to fully load a 350W power box.

Why choose a 48V architecture?

At equal delivered power, higher system voltage reduces ideal current, providing an opportunity to optimize resistive loss and feed-cable routing. Actual installation efficiency depends on the full design, not voltage alone. Compare supplemental feeds, cable length and field-made connections for the same property before claiming savings.

Matched system components

Confirm before ordering

Record the exact fixture revision, connector part number and pinout, track dimensions, illuminated sections, non-lit gaps, feeder lengths, branch protection, total loading, control firmware and applicable location documents. The M12B 10A connector must not be replaced with a lower-rated lead or accessory. Do not parallel independently protected outputs or supplies unless the approved design expressly permits it.

Both the standard and custom cable directions above are 16AWG. SPT-2W is not a thicker-gauge upgrade here; review cable construction, conductor specification, intended use and the complete assembly. Cable type, voltage and module IP rating alone do not establish Wet suitability.

Documents and project support

Review certification evidence · Technical downloads · GC08 capacity guide · Installation and wiring guidance

For an installation, share illuminated section lengths, unlit cable gaps, branch layout and the preferred control platform. For OEM/ODM, include target market, expected order volume, branding and packaging requirements.

Request a C5206 48V configuration review · Explore OEM/ODM support

When should you choose C5206?

Choose C5206 when the project is intentionally designed around a 48V permanent outdoor lighting architecture and the lower current associated with higher system voltage is useful for the planned branch and cable design.

When is C5206 not the first choice?

If the project requires 12V, 24V or 36V fixture options, compare C5204. If the installation requires a compact 24V 9-inch platform, compare C5205 or P23A.

Recommendation evidence

C5206 must be evaluated with the matched 48V GC08 configuration, 16AWG/M12B wiring, protected output limits, branch voltage drop, connector loading and any required power injection. Do not infer a guaranteed maximum fixture count from voltage alone. See the product comparison and recommendation guide.

Technical Documents for C5206 48V

Request the current C5206 48V datasheet, wiring drawing and model-specific certification record. The available SHLED UL E549391 file is not linked here as a C5206 approval.

Published model specifications

Catalog references for technical evaluation. Confirm the current model specification and approved revision before project approval. Empty fields have not been confirmed.

Product series / familyC5206 Series
Model numberC5206
Voltage options (V DC)48
Published power / capacity (W)1.0
LED package / light source5050 RGBW, RGBW 3000K
Color channelsRGBW (3000K white)
CCT options (K)3000
Control protocolSPI
Light spacing9 inch
Units per string5
Wire gauge / constructionStandard: UL2468 16AWG. Custom: SPT-2W 16AWG; both follow the current Damp/Dry configuration route.
Connector familyStandard 48V: M12B 10A. Custom: M12J 10A. Verify the complete harness, pinout and protected-output limits; do not substitute a 5A lead.
Controller / control boxGC08; match voltage and confirm firmware / output configuration
App / firmware routeConfirm the selected control platform and firmware revision
Published IP ratingIP67
Operating temperature-20 to 60°C
Rated lifetime (h)50000
DimensionsØ30 × H16 mm
Beam angle120°
Housing / profile material945U PC, transparent
Certification verification statusConfirm the model-specific certification record, product markings and scope for the supplied configuration before approval.
Verified wet / damp / dry ratingConfiguration offering: Dry/Damp only, not Wet. UL2468 standard or SPT-2W custom assembly must follow the exact finished-product listing, markings and installation instructions; not a blanket certification statement.
Verified Class 2 statusConfirm Class 2 status against the selected power source, output architecture and model-specific documentation.
OEM / ODM scopeDiscuss fixture or enclosure branding, product revisions and the complete roofline-system bill of materials. Feasibility, minimum quantities and validation scope are confirmed in the quotation.

Model and configuration notes

C5206: DC48V, published 1.00W/module reference retained. Standard UL2468 16AWG + M12B 10A. At 9in spacing, 350 modules represent a power-injection planning interval: nominal coverage 262.5ft/80.01m, calculated fixture load 350W, ideal current 7.29A. These are not measured maximum single-ended installation limits. Confirm losses, source current, temperature, end voltage, signal hardware and each protected output. SFQ0401 is currently 12-36VDC, not an assumed 48V accessory.

Specification source

Manufacturer configuration clarification dated 22 October 2026: 48V uses UL2468 16AWG and M12B 10A; 9in power-injection planning interval 350 modules. C5206's published 1.00W/module reference is retained separately from the C5204 0.96W maximum mixed-white clarification. Use model-specific project documentation for installation approval.

Reference documents

Product catalog, credentials & technical documents

Plan the complete configuration

  • Fixture or component format, mounting and intended application.
  • Supply voltage, load and compatible control equipment where applicable.
  • Tracks, connectors, cable and installation accessories.
  • Current model-specific documentation and commercial terms.

Read the system planning guide.

WhatsApp · Talk to G&D SMART

Choose the right person for a quick conversation. WhatsApp opens with a ready-to-send message referencing this page.

WhatsApp opens your chat; please press Send to deliver the message.

Or send an email inquiry

Privacy policy · Project inquiry

Quick Inquiry

Tell us what you need. Our team will get back to you.

Detailed project inquiry