Quick answer: A useful permanent outdoor lighting RFQ must describe the complete system—not just the number of lights and a target price. North American brands, distributors and professional installers should include fixture specifications, spacing, voltage, cable, connectors, mounting track, controller outputs, software, installation environment, sample criteria and forecast quantities.

This practical OEM RFQ checklist and bill-of-materials (BOM) framework helps buyers compare quotations on the same technical basis. You can copy the fields into a spreadsheet, supplier brief or purchasing document.

Why two quotes for “200 ft of permanent lights” may not be comparable

Roofline length is only one dimension. Two 200 ft bids may differ in spacing, fixture wattage, branch count, supplied track, extension cable, controller size, connectors, software configuration, installation documents and replacement parts. A “low price per foot” can exclude costly items that an installer needs to finish and service the job.

Start with a structured RFQ and request a supplier response that identifies included, excluded and optional components.

Part A: the commercial project brief

RFQ field What the buyer should provide
Company and target customer Brand owner, professional installer, distributor, retailer or OEM
Target market United States, Canada or other intended destination; special labeling needs
Sales model Supplier-branded, wholesale, private label, adapted OEM or custom ODM
First application Residential soffit, exposed fascia, light commercial or another layout
Volume forecast Sample quantity, pilot quantity and expected annual range (not a binding order)
Schedule Required sample review, pilot decision and intended launch windows
Quotation terms Destination, agreed Incoterm, currency, packaging, payment and warranty scope
Confidentiality NDA, tooling/data ownership and channel protection requirements, if applicable

Ask the manufacturer to state its proposed MOQ, lead time, tooling cost and production location rather than assume a number from a generic website. Confirm the actual producing entity and shipping documentation for the specific order.

Part B: the fixture and optical specification

Specify the desired look and the measurable electrical characteristics. Use this checklist:

  • Fixture model or reference sample; intended roofline/eave mounting method.
  • DC voltage: 12V, 24V, 36V or 48V as appropriate to the exact model.
  • LED architecture: RGB, RGBW or RGBCW; required dedicated white or tunable white.
  • Maximum simultaneous-channel power per light and how software limits are enforced.
  • Nominal light spacing, total fixture count and allowable spacing variations.
  • Optical effect, beam geometry, color consistency, housing color and dimensions.
  • Specified component ingress rating, ambient operating range and UV/material requirements.
  • Expected fixture life and how it is documented; service-replacement expectations.
  • Target installation environment (Dry, Damp or Wet) with model-specific certification evidence required.

For an existing product reference, review C5204 12V/24V/36V RGBW fixtures or C5205 24V RGBW fixtures. Product specifications and certification statements must be checked against the actual selected revision.

Part C: wiring, signal and power distribution

The RFQ should include a simple roofline drawing, even if it is only a preliminary sketch. Number each segment and identify where the controller can be installed.

Electrical input Specify or request Why it matters
Branch structure Number of outputs and light count per output Defines load and fault isolation
Controller to first light Distance and cable route by branch Voltage drop and data integrity
Unlit extensions Location, length and number of gaps Cable sizing and signal planning
Cable specification AWG, material, construction and environmental marking Current, loss and permitted installation
Connectors Family, keying, pinout, current rating and sealing Prevents incompatible purchases
Output protection Maximum current/power, number of outputs and protection concept Required for a documented electrical design
Power injection Allowed topology, protection and quantity if required Long-run performance and service access
Signal support Amplifier/repeater conditions and installation location Avoids first-light or extension instability

Use the G&D SMART system calculator as a preliminary planning aid, then validate the finished configuration under load. Do not treat the calculator as a safety certification or approval of a maximum run length. See the voltage-drop guide and power-injection guide.

Part D: mounting tracks and installation components

Specify track model, material, finish/color, profile section dimensions, supplied lengths, opening geometry, fastening method and service access. Ask the supplier to show exactly which light models fit each profile and whether the mounting track ships as a separately quoted SKU.

For example, the C5204 Installation Profile A is a model-matched product rather than a universal fit for every fixture family. Review the full tracks and mounting profile range before freezing a BOM.

Part E: controller, firmware and software questions

At minimum, request the controller model and revision, supported system voltage, protected outputs, usable load limit, data protocol, antenna/network needs, local scheduling behavior, supported App platform, firmware version and OTA strategy. For a private-label program, include App branding, account ownership, technical support, cloud/data considerations and optional installer diagnostics as separate line items.

Review the GC08 configurable controller and private-label App scope as reference topics; confirm the functions included in the quoted SKU.

Part F: example BOM template

The table below is a blank procurement structure, not a pre-approved or fully priced kit:

BOM line Supplier model / revision Quantity Approval evidence
Roofline light module/string To be confirmed Per drawing Spec + environmental/certification scope
Matching mounting tracks To be confirmed By linear length Cross-section + fixture compatibility
Controller / power supply To be confirmed By branch design Output schedule + product documents
Connector / extension cables To be confirmed By wire schedule Pinout, AWG, current and cable scope
Power-injection / signal accessories If required Per approved layout Installation detail and protection
Hardware / fastening items To be confirmed By mounting plan Approved installation drawing
Software / branding / manuals Project scope As applicable Release checklist and ownership terms
Spare components Revision-matched list Agreed service stock Compatibility and replacement policy

Procurement tip: Ask for a separate breakdown for standard products, one-time engineering/tooling, test/certification work, packaging and recurring software support. This makes proposals easier to compare without implying that every project needs each cost item.

Part G: acceptance criteria and supplier response

Before approving a purchase order, request a response matrix with the supplier’s compliant / exception / proposal / not applicable answer for each requirement. Define the sample ID and tests needed to close each exception. Typical acceptance categories include:

  • Visual: housing, track fit, lens/beam effect and target white-light behavior.
  • Electrical: measured branch current, first/last module voltage and allowable temperature.
  • Signal/control: setup, offline schedules, recovery behavior and intended App functions.
  • Environment: cable, connector, enclosure and complete-product documentation for the intended use.
  • Commercial: quote validity, MOQ, lead time, warranty, replacements and approved packaging.

Frequently asked RFQ questions

Can I request a single “price per foot” for a complete system?

You can use it for an initial budget, but obtain a line-item BOM and describe the exact light spacing, profile, controller and installation components before comparing suppliers.

Should RFQ sample approval mean the system has received UL approval?

No. Supplier samples, engineering validation and NRTL certification are distinct evidence streams. Confirm current records for the specific model, construction and environment.

Is 24V always preferable to 36V?

No. Choose after reviewing the exact fixture, installation environment, cable, controller, branch loading and required approval route. See the 24V vs 36V selection guide.

Get an apples-to-apples OEM or wholesale quotation

G&D SMART works with professional installer networks, regional lighting brands, distributors and OEM/ODM partners. Use OEM/ODM product development for a custom program or wholesale supply for standard system sourcing.

Send your RFQ: Describe the project and upload/share your specification through the agreed sales channel. Include the target market, product family, initial quantity, required documentation and target sample date.

This RFQ checklist is a purchasing framework. All examples require model-specific verification and a final controlled supplier quote before use as a commercial or safety specification.

Supporting article image Original G&D SMART company-supplied product showroom photo for permanent lighting RFQ and bill of materials planning

WhatsApp · Talk to G&D SMART

Choose the right person for a quick conversation. WhatsApp opens with a ready-to-send message referencing this page.

WhatsApp opens your chat; please press Send to deliver the message.

Or send an email inquiry

Privacy policy · Project inquiry

Quick Inquiry

Tell us what you need. Our team will get back to you.

Detailed project inquiry