Skip to content
Permanent outdoor lighting systems • Hardware, control boxes & OEM/ODM
Discuss Your Project
Menu

G&D SMART / Professional outdoor lighting

350W Permanent Lighting Control Box Capacity

GC08 350W is a control-box capacity option within the configurable G&D SMART permanent-lighting platform.

G&D SMART GC08 permanent lighting control box
GC08 hardware platform. Final branch limits and electrical ratings are confirmed for the selected voltage and project configuration.

Choose voltage first, then capacity

The 350W platform can be configured around 12V, 24V, 36V or 48V project requirements. Select the fixture family and system voltage first, then confirm that 350W is appropriate for the approved light count, branch loading, cable layout and installation conditions.

350W is total platform capacity, not an automatic branch rating

Do not infer individual output limits, Class 2 status or complete-system certification from the 350W headline alone. Review the marked source, branch architecture, protection and model-specific documentation for the supplied configuration.

Typical review checklist

  • Fixture voltage and total project load
  • Number of branches and load per branch
  • Cable gauge, length and voltage-drop budget
  • Signal distance and amplifier placement where required
  • Controller / firmware / App route
  • Protection, enclosure and compliance documentation

View GC08 configuration · Class 2 & control-box documentation · Choose a system voltage


Recommended GC08 Operating Capacity

For system planning, G&D SMART recommends designing around 80% of the GC08 nameplate power, rather than using 100% as the normal operating target.

GC08 version Nameplate power 80% recommended planning power
350W 350W 280W
600W 600W 480W

This 80% value is a recommended system planning/operating target, not a certification limit. Individual output-port limits, wiring, connectors, voltage drop, fixture operating mode and applicable certification requirements must still be checked separately.

For the planning matrix, controller quantity should therefore be calculated using approximately 280W per 350W GC08 or 480W per 600W GC08 of recommended usable system capacity.


GC08 Port-Level and Total-Capacity Rules

The published GC08 platform currently describes 4 protected DC output channels, with up to 150W per output where supported by the selected model configuration. The 350W/600W enclosure rating and each protected output rating are independent constraints.

GC08 model Total nameplate 80% planning load Protected outputs Per-output published ceiling
350W 350W 280W 4 Up to 150W, configuration-dependent
600W 600W 480W 4 Up to 150W, configuration-dependent

Six-output GC08: do not assume six protected outputs or reuse the 150W/output value until the six-output hardware revision and its protection/certification documentation are verified.

Two independent sizing checks

  1. Enclosure total: sum of all active outputs must remain within the selected model's total capacity and G&D SMART 80% planning target.
  2. Each output: each branch must independently remain within the exact output's voltage, current, wattage, protection, connector, cable and voltage-drop limits.

For example, 4 × 150W is a theoretical sum of output ceilings, not permission for a 350W GC08 to deliver 600W. A 350W unit remains subject to its 350W nameplate and 280W planning target; a 600W unit remains subject to 600W nameplate and 480W planning target.

Recommended allocation approach

Allocate branches so that both conditions are met: per-output limits are respected and the sum of all active branch loads per controller stays within its recommended planning capacity. Where connector current is lower than the output ceiling, the connector becomes the limiting component.

Design hold point

Confirm exact voltage-specific model, board revision, port protection trip/current, connector pinout/rating, power supply, thermal limits and certification scope before releasing a wiring BOM. No parallel connection of protected outputs or separate supplies unless explicitly approved by the GC08 design.

Plan your next step with G&D SMART.

Share your application, target market and system requirements.

WhatsApp · Talk to G&D SMART

Choose the right person for a quick conversation. WhatsApp opens with a ready-to-send message referencing this page.

WhatsApp opens your chat; please press Send to deliver the message.

Or send an email inquiry

Privacy policy · Project inquiry

Quick Inquiry

Tell us what you need. Our team will get back to you.

Detailed project inquiry