Complex rooflines do not always follow one straight lighting path. A home may have a front eave, garage return, side elevation, porch, multiple gables and corners that require the lighting run to change direction. The G&D SMART TS2 Signal Splitter is designed to help organize these layouts by routing one compatible SPI data input into two paths: MAIN and BRANCH.

G&D SMART TS2 signal splitter routing permanent roofline lights around gables and multiple house elevations
Example roofline layout showing MAIN and BRANCH signal paths around a complex home outline.

Instead of treating every change in building direction as a separate system, the installer can place the TS2 at a planned branch point and route the two outputs along different parts of the roofline.

Where a TS2 branch can help

  • Left-and-right rooflines: place the splitter near a central point and route MAIN and BRANCH toward opposite sides, where the physical layout and signal direction permit.
  • Gables and eave corners: split at a corner so one route follows the main eave while the other follows a gable or return.
  • Main house and garage: use the two signal paths to organize the main roofline and a connected garage route.
  • Front and side elevations: separate two directions from a practical signal node instead of forcing the installation into one long geometric path.
G&D SMART TS2 signal splitter wiring diagram showing INPUT, MAIN OUTPUT and BRANCH OUTPUT
TS2 connection diagram: connect the incoming data line to INPUT, then route the two signal paths through MAIN and BRANCH.

Understand the three TS2 connections

  1. INPUT: connects to a compatible controller output or to the output of the light string ahead of the splitter.
  2. MAIN OUTPUT: connects to the main lighting route. Light points not assigned to BRANCH remain on MAIN.
  3. BRANCH OUTPUT: connects to the branch route. The branch light-count value is configured in the G&D SMART App.

The TS2 is a signal-routing accessory. It passes the compatible SPI data signal to two wiring paths; it does not provide additional electrical power or increase the controller's power capacity.

Plan the branch point before installing

Start with a simple roofline sketch. Mark each illuminated segment, unlit gap, corner, gable and garage connection. Choose a branch point that allows the MAIN and BRANCH cables to follow practical routes and remain accessible for installation and service.

Record the expected light points on each path. In the G&D SMART App, enter the actual number of light points connected to BRANCH. The main count is calculated from the total light points after the TS2 minus the branch light points.

Keep the total system within its limits

The TS2 supports up to 288 light points combined across MAIN and BRANCH, not 288 points per output. The usable count must also remain within the compatible controller's capacity and the approved limits for fixture power, power supply, cable length, voltage drop and firmware.

For long or demanding runs, verify the signal route and electrical power plan separately. A signal splitter does not correct voltage drop or insufficient power.

Installation checklist

  1. Switch off the controller and power supply before changing any wiring.
  2. Identify INPUT, MAIN OUTPUT and BRANCH OUTPUT and check connector orientation.
  3. Connect the incoming controller or preceding light-string output to INPUT.
  4. Connect the two planned lighting paths to MAIN and BRANCH.
  5. Tighten waterproof connector collars and check that sealing rings are seated correctly.
  6. Secure the TS2; where practical, orient connectors downward or diagonally downward.
  7. Configure the branch point count in the G&D SMART App and verify both routes before restoring power.

When to consider the SA2 signal amplifier

The TS2 manual recommends a compatible SA2 signal amplifier when the input extension before TS2 exceeds 19.69 ft (approximately 6 m). It also recommends SA2 when the controller-to-TS2 signal distance exceeds 39.37 ft (approximately 12 m), or when a TS2 output extension exceeds 39.37 ft (approximately 12 m). Confirm the actual route and compatible equipment before installation.

SA2 strengthens data transmission; it does not inject power.

Frequently asked questions

Does TS2 create two independently powered lighting circuits?

No. It splits the SPI data signal into MAIN and BRANCH routes. It does not add power or create another power supply.

Can each output support 288 lights?

No. The manual specifies up to 288 points total across MAIN and BRANCH combined. Controller, power, cable and firmware limits may reduce the usable count.

Can I use TS2 with any SPI controller?

Use only a compatible controller, fixture voltage, connector pinout and communication protocol. TS2 is configured through the G&D SMART App.

Planning a complex roofline? Review the G&D SMART TS2 Signal Splitter and share your roofline layout, total light count and branch plan with our team.

Discuss your roofline project

WhatsApp · Talk to G&D SMART

Choose the right person for a quick conversation. WhatsApp opens with a ready-to-send message referencing this page.

WhatsApp opens your chat; please press Send to deliver the message.

Or send an email inquiry

Privacy policy · Project inquiry

Quick Inquiry

Tell us what you need. Our team will get back to you.

Detailed project inquiry