How to Configure MAIN and BRANCH Light Counts in the G&D SMART App with TS2

November 17, 2026

The G&D SMART TS2 Signal Splitter has one compatible SPI signal input and two signal outputs: MAIN and BRANCH. Correct App configuration tells the system how many light points are physically connected to the branch route, so the main-route count can be calculated from the total.

G&D SMART TS2 signal splitter product details, pair and reset button and three connection ports
TS2 port identification and Pair / Reset button reference.

Before pairing

  • Confirm the controller, lights and TS2 are a compatible voltage, connector and SPI protocol combination.
  • Install and open the G&D SMART App on the phone and enable Bluetooth.
  • Complete the physical wiring with the system powered off. Connect the incoming signal to INPUT, the main route to MAIN OUTPUT and the branch route to BRANCH OUTPUT.
  • Check the total fixture count and branch count against the installation drawing.

Pair the TS2 with the G&D SMART App

  1. Confirm that the compatible controller and lighting system are correctly connected.
  2. Power the TS2.
  3. Press and hold the Pair / Reset button for approximately 5 seconds to enter pairing or reset mode.
  4. In the G&D SMART App, select Add Device and follow the prompts to pair the signal splitter using Bluetooth and complete Wi-Fi setup.
  5. Confirm that the device appears connected before proceeding.
G&D SMART TS2 signal splitter wiring diagram showing INPUT, MAIN OUTPUT and BRANCH OUTPUT
TS2 connection diagram: connect the incoming data line to INPUT, then route the two signal paths through MAIN and BRANCH.

Set the BRANCH light count

Count the actual light points connected to BRANCH OUTPUT. Enter that number in the TS2 device configuration in the G&D SMART App. The branch light-count value is assigned to BRANCH first.

Main count = total light points after TS2 − branch light points.

For example, if a particular installation has 120 total light points after the splitter and 40 are physically connected to BRANCH, the remaining 80 are assigned to MAIN. This is an arithmetic example only; the final count must remain within the actual controller and system limits.

When to use mirrored effects

When MAIN and BRANCH have the same number of light points, mirrored effects can be enabled where supported by the controller and App configuration. This can be useful for symmetrical rooflines or paired building sections. Verify the effect on the actual installed routes before handover.

Identify and test each route

The TS2 manual suggests using separate physical route identifiers: 01, 02 and so on for MAIN, and B01, B02 and so on for BRANCH. After pairing and configuration, test both routes independently and confirm that the expected light points respond.

Check whether an SA2 signal amplifier is recommended

Signal path location TS2 manual recommendation
Input extension before TS2 Add a compatible SA2 when longer than 19.69 ft (approximately 6 m).
Controller to TS2 Install SA2 when the signal distance is longer than 39.37 ft (approximately 12 m).
TS2 output extension Fit SA2 when the output cable is longer than 39.37 ft (approximately 12 m).

SA2 strengthens data transmission; it does not inject power. If end lights are dim, colors are incorrect or lights flicker, check power capacity and voltage drop separately.

Limits and safety reminders

  • The TS2 maximum is up to 288 light points combined across MAIN and BRANCH, not 288 per output.
  • Usable light count also depends on controller capacity, fixture power, power-supply capacity, cable length, voltage drop and system firmware.
  • TS2 is a signal splitter, not a power-injection T-connector. Do not connect two power supplies directly to the same lighting string.
  • Power off the controller and supply before wiring changes. Never connect or disconnect waterproof connectors while powered.
  • Do not submerge TS2 or install it where water can collect. Do not open its potted housing.

Frequently asked questions

Does TS2 automatically detect the branch light count?

The manual instructs the installer to enter the actual BRANCH light-point count in the G&D SMART App. Do not assume automatic physical counting.

What happens to the light points not assigned to BRANCH?

They remain on MAIN. The main count is the total points after TS2 minus the branch points.

Can the SA2 solve a low-voltage problem?

No. SA2 strengthens the data signal. It does not provide power or correct voltage drop.

View the G&D SMART TS2 Signal Splitter or contact our team for setup support.

WhatsApp · Talk to G&D SMART

Choose the right person for a quick conversation. WhatsApp opens with a ready-to-send message referencing this page.

WhatsApp opens your chat; please press Send to deliver the message.

Or send an email inquiry

Privacy policy · Project inquiry

Quick Inquiry

Tell us what you need. Our team will get back to you.

Detailed project inquiry